Lighting rebates / New Hampshire
NHSaves Commercial Lighting Incentives
Fill the NHSaves Lighting Inventory Workbook from your audit.
NHSaves pays prescriptive incentives for commercial and industrial lighting retrofits in New Hampshire, per fixture and per control, from a product code table. LumaQuote fills the program's Lighting Inventory Workbook from your site audit, including the code, rated watts and unit incentive on each line.
Start free See how the fill works
Works on every plan, Free included. You still submit to NHSaves yourself.
Checked on NHSaves's own site on November 13, 2026: 2026 NHSaves C&I Retrofit Lighting Incentive form.
Program
2026 Commercial and Industrial Retrofit, Lighting Incentive. Form dated January 1, 2026.
Pre-approval
Required before installation. The utility may inspect the existing lighting first, and it must be in place and working.
Budget
Incentives are pre-approved within program budget caps. Incentive plus all other funding can't exceed the project cost.
Program file
Lighting Inventory Workbook (Excel), attached inside the 2026 form. Open the PDF in Adobe Acrobat and save the attachment.
Not combined
Equipment bought through the NHSaves midstream instant incentive, or paid by another NHSaves program, isn't eligible.
What it pays
NHSaves lighting incentives in 2026
Table A and Table B from the 2026 form. Each fixture code also has a minimum average watts saved per new fixture.
| Product | Incentive |
|---|---|
| 10L linear LED tubes in existing sockets | $5 per tube (10 W saved per tube). |
| 20L and 30L troffers, retrofit kits and linear ambient fixtures | $60 per fixture (32 W saved). |
| 40L low bay, 41L high bay | $125 and $175 per fixture (95 W and 150 W saved). |
| 70L and 71L garage and canopy | $75 and $100 per fixture. |
| 80L to 91L exterior and pole fixtures (auto-controlled) | $75 to $200 per fixture. |
| 99L LED fixtures not covered by another code | $20 per fixture. |
| Controls (Table B) | Wall sensor $20, remote ceiling sensor $30, integral dual sensors $35 per fixture, networked $45 per fixture, high bay integral occupancy $25 per fixture. |
Systems must average at least 2,000 operating hours a year. Table A products must be DLC listed (99L may be ENERGY STAR), and linear tubes can't use 99L. Networked controls need the DLC QPL, commissioning, a control narrative and the NHSaves Performance Testing form.
How a project goes
From audit to payment with NHSaves
- 1
Call the utility first
A pre-installation inspection may be needed.
- 2
Send Steps 1 to 3 with the workbook
To your utility's efficiency contact: Eversource, Liberty, NHEC or Unitil. Include cut sheets with photometric tables.
- 3
Wait for the signed offer
The pre-approval is valid once the utility signs and dates it. Don't sign Steps 5 or 6 until the utility tells you to.
- 4
Finish by the Offer Valid Through date
Then send the final signed application with proof of purchase. The incentive is calculated on as-installed conditions.
The program file
What LumaQuote fills in the Lighting Inventory Workbook (2026)
On the Rebates step, LumaQuote checks the project, asks the program's own questions once, then fills NHSaves's file and gives it back to you. Your formulas, dropdowns and protection stay as the program built them.
Filled from your audit
- Table 1C: existing device code and rated watts for each line
- The Table A product code, with the unit incentive from the 2026 table
- Quantities, manufacturer and model, watts and hours
- Table 1D: one fixture-mounted sensor row per controlled line
- Up to 25 lines
You finish in the file
- DLC Premium or Standard for each line (Table 1C, column L)
- Manufacturer and model wherever it is still blank (column J)
- A device code for any existing fixture LumaQuote couldn't match, from the Existing Device Codes tab
LumaQuote doesn't have these, so it lists them after the download.
What LumaQuote decided
- LumaQuote flags any line that saves fewer watts per new unit than its product code needs.
- Lumen ranges for the product code are estimated from LED watts at about 130 lm/W. Check them against each spec sheet.
- Controls go in as one fixture-mounted sensor per fixture (codes 62, 63 or 65). Change the code and counts for wall or ceiling sensors.
Only cells a person could type in are written. If NHSaves moves an input cell in a new version, LumaQuote skips it and tells you. See a worked example
Before you submit
Four checks on every NHSaves lighting job
1
Pre-approval before anything ships
Installing before the signed offer loses the incentive.
2
2,000 hours
The system has to average 2,000 hours a year. Check hours per space, not just the building schedule.
3
Watts saved per code
Each code has a minimum average watts saved per new fixture. Low-wattage existing fixtures can miss it.
4
Pick one path
Midstream instant incentive equipment can't go on this application.
Show the NHSaves incentive as an estimate
The program sets the final number after its review. LumaQuote marks every incentive line in the proposal as an estimate, separate from the LED and controls savings, so the customer sees what is confirmed and what isn't.
FAQ
NHSaves lighting incentives: common questions
Which utilities are in the NHSaves commercial lighting program?
Eversource, Liberty, New Hampshire Electric Co-op and Unitil. Steps 1 to 3 of the application go to your utility's efficiency contact by email.
Does an NHSaves lighting project need pre-approval?
Yes. NHSaves says projects need to be pre-approved before installation to be eligible, and a utility site inspection may be required. The offer is valid only once the utility signs and dates it.
Where is the NHSaves Lighting Inventory Workbook?
It is attached inside the 2026 C&I Retrofit Lighting Incentive PDF. Open the PDF in Adobe Acrobat and save the attachment, then drop it into LumaQuote.
Can I use NHSaves instant discounts and the retrofit application on the same fixtures?
No. Equipment bought through the NHSaves midstream instant incentive program, or paid by another NHSaves program, isn't eligible for the retrofit incentive.
What is the minimum operating hours for NHSaves lighting?
Lighting systems must average at least 2,000 operating hours a year, calculated as total kWh divided by total kW.
Is the NHSaves fill on the Free plan?
Yes. The verified program files, NHSaves included, work on every LumaQuote plan.
NHSaves links: 2026 retrofit lighting form and workbook
Audit on site. Get the NHSaves file filled.
Capture the job on iPad, phone or desktop, then let LumaQuote fill the program's file and build the proposal from the same data. Free plan, no credit card.
Questions: info@lumaenergy.ca
Other program files LumaQuote fills: Energy Trust of Oregon Idaho Power BGE Rhode Island Energy All lighting rebates