Photometric Plan Calculator
Enter the room and the fixture, or upload its IES file, and get a point-by-point light map, the fixture count that meets your target, and how it compares with the existing lighting. Download a client-ready PDF. Free, no sign-up.
Photometric plan calculator
Enter the space type, which sets the target light level, then the room length, width and mounting height. Upload the proposed fixture's IES file or use a generic fixture with lumens, watts and a light distribution (very wide, wide, medium or narrow). The layout is either automatic (the fewest fixtures on an even grid that reach the target with good evenness), a number of fixtures, or rows and columns. Turn on Compare to add the existing lighting: pick a common fixture such as a 3-lamp T8 troffer, a 4-lamp T5HO or a 400 W metal halide high bay, or enter its lumens and watts, and the number of fixtures.
Results show whether the proposed layout meets the target, a light map with a target contour, values and fixtures to scale, a calculation summary (average, minimum, maximum, avg:min and max:min, spacing with spacing to mounting height, load, power density and energy a year) for existing and proposed side by side, a luminaire schedule, and the energy and cost saved a year. Advanced settings: room finishes, work plane height, light loss factor, the border left out of the stats, hours a year, electricity rate and turning the fixtures 90 degrees. Download a two-page PDF with your company and client name, or copy a link to the plan.
IES file viewer
An uploaded IES file shows its polar candela plot, manufacturer, catalog number, lumens calculated from the candela data and from the file header, input watts, efficacy, beam angle at 50 percent and field angle at 10 percent of peak intensity, peak candela, the share of light going down, symmetry and file format.
What is a photometric plan?
A photometric plan is a drawing that shows the light level, in foot-candles or lux, at points across a floor or site, calculated from each fixture's IES photometric file. It proves a lighting layout delivers enough light, evenly enough, before anything is ordered or installed.
A typical photometric plan includes:
- Fixture locations and a fixture schedule with catalog numbers, lumens, watts and mounting heights.
- A grid of calculated values across the floor or site, often with contour lines (isolines) joining equal light levels.
- A statistics table with the average, maximum and minimum light level and the uniformity ratios.
- The assumptions: work plane height, light loss factor and, in full software, room surface reflectances.
The calculator above produces the core of one for an open rectangular room: the point grid with values and a target contour, a calculation summary, a luminaire schedule and the assumptions, in a PDF you can hand to a client.
When you need a photometric plan
- Site plan approval. Many towns ask for a photometric plan with parking lot and outdoor lighting, to check light levels and light spilling past the property line.
- Code minimums. Egress paths have minimum light levels. The International Building Code, for example, calls for an average of 1 foot-candle and a minimum of 0.1 foot-candle along the egress path on emergency power. Check the code your jurisdiction adopted.
- A client or engineer's specification that sets target light levels and uniformity ratios.
- Retrofits that change the layout. When you remove fixtures, change the count, or swap a fixture type with a different light spread, a quick photometric check shows the client the space won't go dark.
- Warehouses with racking, gyms and manufacturing, where uneven light causes safety and quality problems.
A straight one-for-one LED retrofit with similar optics usually doesn't need one. Turn on Compare above when you want to show the client the new layout against what's there today: light levels, evenness, load and energy side by side.
Photometric plan vs photometric study
People use the two terms for the same thing. Strictly, the photometric study is the calculation and its report, and the photometric plan is the drawing that comes out of it. Lighting reps, engineers and permit offices may ask for either one and mean a layout drawing with point-by-point values and a statistics table.
How to read a photometric plan
| Number | What it tells you |
|---|---|
| Average | The overall light level. Compare it with the target for the space. |
| Minimum | The darkest point. Codes and specs often set a minimum, especially for egress and parking. |
| Maximum | The brightest point, usually right under a fixture. |
| Average to minimum (avg:min) | How even the light is. Lower is better. 3:1 means the darkest point gets a third of the average. |
| Maximum to minimum (max:min) | The spread between the brightest and darkest points. Common in parking and outdoor specs. |
Look at the map as well as the numbers. A good average with a poor minimum usually means dark bands along the walls or between rows, which the map shows straight away.
Typical light levels and uniformity
| Space | Typical average (fc) | Common uniformity rule of thumb |
|---|---|---|
| Office, classroom | 30 to 50 | avg:min 3:1 or better |
| Retail sales floor | 30 to 75 | avg:min 3:1 or better |
| Manufacturing | 30 to 75 | avg:min 3:1 or better |
| Warehouse, open floor | 15 to 30 | avg:min 3:1 to 4:1 |
| Gymnasium | 30 to 75 | avg:min 3:1 or better |
| Parking garage | 5 to 10 | max:min about 10:1 |
Typical design values based on common IES guidance and practice. A project specification or code governs where it sets a number.
What is an IES file?
An IES file is a plain text file, in the IES LM-63 format, that lists how much light a fixture sends in each direction, in candela, at a grid of vertical and horizontal angles. A photometric lab measures it on a goniophotometer. The file also holds the manufacturer, catalog number, lumens and input watts.
Manufacturers post IES files on each product page, usually under Downloads or Photometry, one per catalog number. Pick the file for the exact lumen package, color temperature and optic you're quoting, because a different optic changes the light spread even at the same lumens.
How to view an IES file
Upload it to the calculator above. It shows the polar candela plot, lumens worked out from the candela data, input watts, efficacy, beam and field angles, peak intensity, how much light goes up, and the symmetry the file uses. If the lumens in the file header don't match the candela data, both are shown. Type C files (the normal type for indoor fixtures and most area lights) are supported. Type B files, used for floodlights and sports lighting, are not.
How the point-by-point calculation works
For each point on the work plane and each fixture, the calculator looks up the fixture's candela toward that point from the IES file and applies the inverse square cosine law:
Foot-candles = candela × cos³(angle from straight down) ÷ mounting height above the work plane²
It adds the light from every fixture at every point, then multiplies by the light loss factor. Example: a high bay with 6,000 candela straight down, 25 ft above the floor, puts 6,000 ÷ 625 = 9.6 fc directly below it, before the light loss factor. At 25 ft to the side, the angle is 45°, so the same fixture adds candela × 0.354 ÷ 625 at that point.
Light that bounces off the ceiling, walls and floor is then estimated from the room finishes you pick (for example 80% ceiling, 50% walls, 20% floor) and added evenly across the floor. In an office with light finishes this adds a good share of the total. In a tall warehouse with a dark open deck it adds much less.
Auto layout tries even grids from the fewest fixtures up and keeps the first one whose average reaches the target with an average to minimum ratio of 3:1 or better (4:1 for warehouses, corridors and garages). The count and the map always come from the same calculation.
What this calculator is built for
Open rectangular rooms with fixtures on an even grid: offices, classrooms, retail floors, open warehouses, gyms and manufacturing areas. It reads any Type C IES file, estimates reflected light from the room finishes, applies a light loss factor and a border, works in feet and foot-candles or meters and lux, and compares the proposed layout with the existing lighting on the same color scale.
Racking, mezzanines, vertical light on shelves, sloped ceilings, odd room shapes, outdoor site plans with poles and property lines, and emergency egress paths need a full lighting design program. For those, or for a design that has to be stamped or submitted, use AGi32, DIALux or Visual, or ask the manufacturer's rep for a layout.
From photometric plan to proposal
Picked a layout? LumaQuote turns it into an area-based lighting audit with LED options, utility rebates, installation costs and a client-ready proposal.
Click "Build a proposal" under the results. The room, fixture count, watts and the existing lighting carry into a new project, and you can change everything there. See what a lighting audit covers and how to build a lighting retrofit proposal that wins the job.
Start freeFree plan: 3 complete proposals, no credit card.
Photometric plan FAQ
What is a photometric plan?
A drawing that shows calculated light levels, in foot-candles or lux, at points across a floor or site, based on each fixture's IES file. It includes fixture locations, a grid of values and a statistics table with the average, maximum, minimum and uniformity ratios.
Do I need a photometric plan for an LED retrofit?
Usually not for a one-for-one swap with similar optics. It helps when you change the fixture count or layout, switch to a fixture with a different light spread, or the client or a specification asks you to prove the light levels. The comparison on this page shows the existing lighting and the proposed layout side by side.
What is a good uniformity ratio?
For general indoor lighting, an average to minimum ratio of 3:1 or better is a common rule of thumb, and 2:1 or better looks very even. Open warehouse floors often accept 3:1 to 4:1. Parking garages are often designed to about 10:1 maximum to minimum. A project specification or code governs where it sets a number.
Where do I find IES files?
On the manufacturer's product page, usually under Downloads, Photometry or Specifications, listed by catalog number. Distributors and manufacturer reps can send them too. Use the file that matches the exact lumen package and optic you're quoting.
What's the difference between the lumen method and point-by-point?
The lumen method gives one average light level for the room from the fixture lumens, a coefficient of utilization and a light loss factor. It's quick and good for counting fixtures. Point-by-point calculates the light at many points from the fixture's candela distribution, so it shows minimums, dark spots and uniformity that an average hides.
Does it include light reflected off the walls and ceiling?
Yes. Direct light is calculated point by point, then the light reflected off the ceiling, walls and floor is estimated from the room finishes and added evenly. Pick the finishes under Advanced settings. Light meter readings on new fixtures can still come in higher, because the light loss factor lowers the calculated values to allow for aging and dirt.
Can I use this for a parking lot or outdoor site plan?
This calculator is built for indoor rooms. Site plans need pole locations, mounting heights, tilts and calculations at the property line: use AGi32 or Visual, or ask the fixture manufacturer for a site photometric plan.
Does this replace AGi32 or DIALux?
It's a quick, free check for scoping and proposals: open rectangular rooms on even grids, with reflected light estimated. AGi32, DIALux and similar tools model full room geometry, obstructions and outdoor sites, and produce drawings for permits and engineers.