Wattage Selectable LED Fixtures: Keep Settings Clear From Audit to Order

A wattage selectable LED fixture needs two identifiers in a retrofit scope: the complete model number and the setting intended for each space. Carry the selected output, color temperature and corresponding input watts through the estimate, installation instructions and final record. A product code alone can leave several different lighting results open.
Examples are illustrative, and project inputs must be verified.
For a distributor, the practical question is whether the order tells the installer what to deliver in each room. For an ESCO, it is whether the proposed energy calculation describes the setting that will actually be installed. Start with the same field record, then keep those two decisions connected.
Separate the model, the setting and the watts
Manufacturers describe adjustable products in different ways. A selector may be labeled with watts, lumens or output levels. Another selector may set correlated color temperature, or CCT, in kelvins. Copy the actual labels from the product documentation rather than turning every selector into a generic low, medium or high wattage choice.
Use three pieces of information together:
Record | What belongs in it | Why it matters |
|---|---|---|
Product identity | Manufacturer, complete model and relevant options | Identifies the equipment being supplied |
Intended configuration | Output-selector position and CCT for the named space | Tells the installer how that equipment should be configured |
Performance reference | Input watts and lumens for that combination, with cut-sheet revision | Supports the energy estimate and lighting review |
A purchase quantity can combine identical models, while the installation schedule still separates settings by room. Keep that room-level breakdown with the order. The same carton can serve two spaces that need different configurations.
The broader lighting audit template covers the existing fixture, quantity and space information that anchors this record.
Read the performance table at the selected CCT
The Lithonia Lighting Contractor Select CPANL specification, revised April 30, 2026, shows why the configuration matters. For model CPANL 2X2 ALO1 SWW7 M4 at 4000 K, its performance table lists:
Output setting | Input power | Light output |
|---|---|---|
Low | 20.9 W | 2,750 lm |
Medium | 29.4 W | 3,930 lm |
High | 38.8 W | 5,031 lm |
The sheet also identifies the shipping setting as highest output and 4000 K. Its electrical notes recommend the high setting for optimal 0-10V dimming performance. Read those notes alongside the performance table when defining a controls package.

At 4000 K, the CPANL 2x2 performance table assigns different watts and lumens to each output setting.
Select the lighting result before settling on the lowest input power. The DOE commercial LED purchasing guide calls for adequate lighting for the task and comparison of light output and distribution. Review the selected configuration against the layout, mounting height, room surfaces and visual work. A setting change can require another lighting review even when the model number stays the same.
Catch the field mistake before it reaches the quote
A common mistake is photographing a selectable fixture's nameplate and recording the lowest wattage printed on it as the existing load. The label may show the available range while the installed selector remains at a higher output. The auditor has identified the family but has left the operating configuration unresolved.
In a warehouse office wing, that error can spread quickly when one inspected fixture becomes the assumed baseline for every room. Some panels may have been reset during earlier maintenance. Others may have been replaced with a newer revision. An estimator who applies one unverified setting to the entire wing can misstate both the baseline and the expected reduction.
Record the observed configuration where it can be verified, the rooms it represents and the source of its input watts. If access prevents confirmation, name the affected group and the required follow-up in the audit notes. A close-up of the selector label, tied to a room and fixture reference, answers more than an unlocated photograph of a carton.
Follow the manufacturer's isolation and adjustment instructions when checking or changing selector settings.
Write a setting instruction that survives purchasing
Keep product selection and room assignment together. An instruction such as “adjustable panel, 4000 K” still leaves output unresolved. A usable line identifies the space, fixture reference, full model, quantity, output setting, CCT and source for the corresponding watts.
For an office wing, separate the open office and corridor if the lighting review calls for different settings. Purchasing can total the shared model for procurement, while the installer receives the configuration by space. Give any required mounting or controls accessories their own order references so a combined product total does not hide them.
Before issuing the order, compare the supplier's complete model string with the selected submittal. Check the voltage, mounting arrangement, controls compatibility and configuration instructions. If the supplier offers a substitute, repeat the setting and performance review using that model's documentation. Similar selector labels can correspond to different power and light output.
Where incentives depend on product qualification, retain the exact listing and program evidence with the selected configuration. The DLC Premium versus Standard guide explains the wider product and program checks. Keep any utility-specific calculation method tied to the actual program serving the site.
Quantify the cost of a setting mismatch
For a US office project, assume 60 panels are specified at a 30 W setting but installed at a 40 W setting. With 3,000 annual operating hours and US$0.15 per kWh, the difference is:
Additional power per panel: 40 W minus 30 W = 10 W.
Additional connected load: 60 panels × 10 W = 600 W.
Convert to kilowatts: 600 W ÷ 1,000 = 0.6 kW.
Additional annual energy: 0.6 kW × 3,000 hours = 1,800 kWh.
Additional annual energy cost: 1,800 kWh × US$0.15/kWh = US$270.
That is the energy-cost gap between the two settings with the same operating hours. Keep controls effects, demand charges and maintenance outside this calculation. If the higher output is needed to meet the lighting requirement, update the proposed watts and financial forecast to match it.
The lighting retrofit proposal guide shows where the selected equipment, scope and financial assumptions belong in the customer document.
Close the loop from the audit to the installed record
During the walkthrough, organize fixture groups by the spaces where a setting decision will matter. In LumaQuote Field, capture fixtures, quantities, photos and site notes by area and space. Work offline on site, then sync the audit and photos for desktop review. The estimator can review the location, count and supporting image together before choosing the replacement.
Use a consistent room and fixture reference in the field notes, proposed configuration schedule and installer instructions. At closeout, reconcile the installed model, quantities and settings against the issued schedule. Record any accepted change with its location, then update the energy calculation and proposal record where needed.
Start with one area on the free plan and carry its counts, photos and setting notes through desktop review.
Practical questions
Can one model be used at different settings in the same project?
Yes, where its documented configurations meet the requirements of each space. Total the identical models for purchasing, and preserve a separate setting assignment for each room or fixture group.
Which wattage belongs in the proposed energy calculation?
Use the documented input watts for the selected model, output position and CCT. Keep the source revision with that value, and revise the calculation when the accepted installed configuration changes.
What evidence should the auditor photograph?
Capture the complete product label and, where safely accessible, the selector position and its legend. Tie those images to a space and fixture group so another reviewer can tell which installed equipment they describe.